Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
J Prosthodont ; 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38526464

RESUMO

PURPOSE: This study evaluated the effect of toothbrushing cycles on surface roughness (Ra), gloss (GU), and morphology of two zirconia finishing and polishing protocols. MATERIALS AND METHODS: An ultra-translucent zirconia disc was sectioned into rectangular plates (12 mm × 7 mm × 3 mm) and divided into two groups according to the polishing and finishing system used (diamond rubber abrasive/DRA or glazing/GLA). Bovine enamel (BEN) plates with the same dimensions were used as a Control. Specimens of zirconia and enamel were analyzed for Ra and GU (n = 11) and surface morphology by scanning electron microscopy (n = 3) before toothbrushing (baseline) and after 15,000 and 30,000 toothbrushing cycles. Ra and GU data were analyzed by ANOVA two-way and post-hoc Tukey's test (α = 0.05), while the surface morphology was analyzed qualitatively. RESULTS: The Ra decreased significantly after 30,000 toothbrushing cycles for DRA and GLA zirconia ceramics. DRA showed a higher GU at the baseline, after 15,000 and 30,000 toothbrushing cycles than GLA and BEN. Toothbrushing polished the zirconia, creating a smooth surface, while no changes were observed for BEN. CONCLUSIONS: The increase in toothbrushing cycles (30,000) changed the surface roughness of DRA and GLA zirconia ceramics. DRA zirconia presented the highest GU, which did not change with toothbrushing.

2.
Dent Mater ; 40(4): e12-e23, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38368137

RESUMO

OBJECTIVE: this study evaluated dentin microtensile bond strength (µTBS) and failure modes (at 24 h and one year), bonding interface regarding hybridization, surface morphology regarding demineralization, in situ metalloproteinase (MMP) activity, and antibacterial effect of three dentin etchants compared to 35% phosphoric acid (PA). MATERIALS AND METHODS: The Adper Single Bond 2 adhesive (3 M Oral Care) was applied on moist dentin etched with PA (control) or on air-dried dentin etched with 3% aluminum nitrate + 2% oxalic acid (AN), 6.8% ferric oxalate + 10% citric acid (FO), or 10% citric acid (CA). The µTBS test used 40 human teeth (n = 10). Failure modes and surface morphology were analyzed by scanning electron microscopy (n = 3), while bonding interface morphology and MMP activity were evaluated by laser scanning confocal microscopy (n = 3). Antibacterial activity was evaluated against S. Mutans biofilm by means of viable cells count (CFU/mL). RESULTS: PA presented the highest bond strengths regardless of aging time. PA, AN, and CA showed stable bond strengths after one year of storage. Adhesive and mixed failures were predominant in all groups. Thin hybrid layers with short resin tags were observed for the experimental etchants. The AN-based etchant was able to inhibit MMP activity. All tested etchants presented antibacterial activity against S. Mutans biofilm. SIGNIFICANCE: This study suggests different dentin etchants capable of inhibiting MMP activity while also acting as cavity disinfectants.


Assuntos
Resinas Compostas , Colagem Dentária , Compostos Férricos , Humanos , Resinas Compostas/química , Adesivos Dentinários/farmacologia , Adesivos Dentinários/química , Cimentos de Resina/farmacologia , Cimentos de Resina/química , Microscopia Eletrônica de Varredura , Dentina/química , Ácido Cítrico/farmacologia , Antibacterianos/farmacologia , Resistência à Tração , Teste de Materiais
3.
Braz Dent J ; 34(5): 63-71, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38133474

RESUMO

This study evaluated the effect of toothbrushing on enamel-cementing material-ceramic bonded interfaces, using different cementing materials. MATERIALS AND METHODS: Thirty enamel and thirty ceramic blocks were bonded with cementing materials to produce the samples that were bonded with three types of cementing materials: 1- RelyX Ultimate resin cement (REXU), 2- RelyX Unicem 2 self-adhesive resin cement (REU2) and 3- heated Z100 restorative composite (60°C). Bonded interfaces of the samples were toothbrushed and the surfaces of the 3 cementing materials were evaluated for roughness (RG, in µm), roughness profile (RP, in µm), and volume loss (VL, in µm3) (baseline and after 20,000 and 60,000 toothbrushing cycles). Data were evaluated by Generalized Linear Analysis (two factors: "material" and "toothbrushing cycle") and Bonferroni test (α=0.05). RESULTS: REXU and Z100 exhibited lower RG than that presented by REU2, except after 60,000 toothbrushing cycles when only Z100 differed from REU2. The increase in toothbrushing cycles increased the RG and RP for all materials. REU2 also showed higher RP than those showed by REXU and Z100 when it was analyzed regarding the enamel. The VL of Z100 was the lowest with 20,000 toothbrushing cycles, regarding the enamel and ceramic. For 60,000 cycles, REXU showed the lowest VL regarding the ceramic, and REU2 had the highest VL regarding the enamel and ceramic. CONCLUSION: In general, REXU and Z100 showed the best results regarding the evaluations performed and the REU2 exhibited the highest RG, RP, and VL.


Assuntos
Cimentos de Resina , Escovação Dentária , Porcelana Dentária , Resinas Compostas , Cimentos Dentários , Cimentos de Ionômeros de Vidro , Cerâmica , Esmalte Dentário , Propriedades de Superfície , Teste de Materiais
4.
Braz. dent. j ; 34(5): 63-71, Sept.-Oct. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - odontologia (Brasil) | ID: biblio-1528017

RESUMO

Abstract This study evaluated the effect of toothbrushing on enamel-cementing material-ceramic bonded interfaces, using different cementing materials. Materials and Methods: Thirty enamel and thirty ceramic blocks were bonded with cementing materials to produce the samples that were bonded with three types of cementing materials: 1- RelyX Ultimate resin cement (REXU), 2- RelyX Unicem 2 self-adhesive resin cement (REU2) and 3- heated Z100 restorative composite (60°C). Bonded interfaces of the samples were toothbrushed and the surfaces of the 3 cementing materials were evaluated for roughness (RG, in µm), roughness profile (RP, in µm), and volume loss (VL, in µm3) (baseline and after 20,000 and 60,000 toothbrushing cycles). Data were evaluated by Generalized Linear Analysis (two factors: "material" and "toothbrushing cycle") and Bonferroni test (α=0.05). Results: REXU and Z100 exhibited lower RG than that presented by REU2, except after 60,000 toothbrushing cycles when only Z100 differed from REU2. The increase in toothbrushing cycles increased the RG and RP for all materials. REU2 also showed higher RP than those showed by REXU and Z100 when it was analyzed regarding the enamel. The VL of Z100 was the lowest with 20,000 toothbrushing cycles, regarding the enamel and ceramic. For 60,000 cycles, REXU showed the lowest VL regarding the ceramic, and REU2 had the highest VL regarding the enamel and ceramic. Conclusion: In general, REXU and Z100 showed the best results regarding the evaluations performed and the REU2 exhibited the highest RG, RP, and VL.


Resumo Este estudo avaliou o efeito da escovação nas interfaces de união esmalte-material cimentante-cerâmica, utilizando diferentes materiais cimentantes. Materiais e Métodos: Trinta esmaltes e trinta blocos cerâmicos foram unidos com materiais de cimentação para produzir as amostras que foram unidas com três tipos de materiais de cimentação: 1- cimento resinoso RelyX Ultimate (REXU), 2- cimento resinoso autoadesivo RelyX Unicem 2 (REU2) e 3-compósito restaurador aquecido Z100 (60°C). As interfaces coladas das amostras foram escovadas e as superfícies dos 3 materiais cimentantes foram avaliadas quanto à rugosidade (RG, em µm), perfil de rugosidade (RP, em µm) e perda de volume (VL, em µm3) (baseline e após 20.000 e 60.000 ciclos de escovação). Os dados foram avaliados por Análise Linear Generalizada (dois fatores: "material" e "ciclo de escovação") e teste de Bonferroni (α=0,05). Resultados: REXU e Z100 apresentaram menor RG do que REU2, exceto após 60.000 ciclos de escovação, quando Z100 diferiu apenas de REU2. O aumento dos ciclos de escovação aumentou o RG e RP para todos os materiais. O REU2 também apresentou PR maior que o REXU e Z100, quando analisado em relação ao esmalte. O VL de Z100 foi o menor com 20.000 ciclos de escovação em relação ao esmalte e cerâmica. Para 60.000 ciclos, o REXU apresentou o menor VL em relação à cerâmica e o REU2 o maior VL em relação ao esmalte e à cerâmica. Conclusão: De maneira geral, REXU e Z100 apresentaram os melhores resultados nas avaliações realizadas e o REU2 apresentou os maiores RG, RP e VL..

5.
Restor Dent Endod ; 47(3): e32, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36090509

RESUMO

Objectives: This study aimed to evaluate the influence of inorganic composition and filler particle morphology on the mechanical properties of different self-adhesive resin cements (SARCs). Materials and Methods: Three SARCs including RelyX Unicem-2 (RUN), Maxcem Elite (MAX), and Calibra Universal (CAL) were tested. Rectangular bar-shaped specimens were prepared for flexural strength (FS) and flexural modulus (FM) and determined by a 3-point bending test. The Knoop microhardness (KHN) and top/bottom microhardness ratio (%KHN) were conducted on the top and bottom faces of disc-shaped samples. Sorption (Wsp) and solubility (Wsl) were evaluated after 24 hours of water immersion. Filler morphology was analyzed by scanning electron microscopy and X-ray energy dispersive spectroscopy (EDS). FS, FM, %KHN, Wsp, Wsl, and EDS results were submitted to 1-way analysis of variance and Tukey's post-hoc test, and KHN also to paired t-test (α = 0.05). Results: SARC-CAL presented the highest FS value, and SARC-RUN presented the highest FM. SARC-MAX and RUN showed the lowest Wsp and Wsl values. KHN values decreased from top to bottom and the SARCs did not differ statistically. Also, all resin cements presented carbon, aluminum, and silica in their composition. SARC-MAX and RUN showed irregular and splintered particles while CAL presented small and regular size particles. Conclusions: A higher mechanical strength can be achieved by a reduced spread in grit size and the filler morphology can influence the KHN, as well as photoinitiators in the composition. Wsp and Wsl can be correlated with ions diffusion of inorganic particles.

6.
J Esthet Restor Dent ; 34(7): 1051-1059, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35644927

RESUMO

OBJECTIVES: To evaluate the influence of dentin pretreatments on the push-out bond strength (POBS) of self-adhesive resin cements (SARCs) to radicular dentin. MATERIALS AND METHODS: Two experimental pretreatments (2.5% titanium tetrafluoride (TiF4 ) and 26% polyacrylic acid (PA)) and two SARCs: Maxcem Elite (MAX) and Calibra Universal (CAL) were used. For each cement, a control group was applied as indicated by the manufacturer. Sixty bovine incisors were restored (n = 10) and subjected to POBS evaluation. Failure mode, adhesive interface and surface morphology were analyzed by a Scanning Electron Microscopy (SEM) and resin infiltration was performed by confocal laser scanning microscopy (CLSM). Data for POBS and CLSM were analyzed by three-way ANOVA and Bonferroni post-hoc (α = 0.05). RESULTS: For MAX, both experimental pretreatments resulted in increased POBS in the cervical third, and for CAL, only the PA resulted in higher POBS in the cervical third. The most failures occurred between the dentin and the resin cement, except when TiF4 was applied. For PA, analysis of surface morphology showed open dentinal tubules, while TiF4 presented particle agglomerates. SEM and CLSM images confirmed presence of resin tags for both pretreatments. CONCLUSION: Pretreating radicular dentin with PA and TiF4 solutions improves the bond strength of SARCs.


Assuntos
Colagem Dentária , Cimentos de Resina , Animais , Bovinos , Colagem Dentária/métodos , Cimentos Dentários/química , Análise do Estresse Dentário , Dentina , Adesivos Dentinários/química , Teste de Materiais , Cimentos de Resina/química , Propriedades de Superfície
7.
Clin Oral Investig ; 26(8): 5189-5203, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35441897

RESUMO

OBJECTIVE: Investigate the effect of erosive challenge with hydrochloric acid (HCl) on the surface of five different restorative materials. MATERIAL AND METHODS: Ten plates of five restorative materials (Admira Fusion, Activa BioActive-Restorative, Charisma, Equia Forte HT Fil/EF, Filtek Universal Restorative/FU) were obtained. Half of the plate surfaces was covered with an adhesive tape, creating a control area, and the other side was submitted to the HCl (0.06 M HCl; pH 1.2; at 37 °C; for 30 h). Plates with control and HCl-treated areas were analyzed regarding the surface roughness (Sa), roughness profile (Rv), surface loss (SL), microhardness (MI), and gloss (GL) (n = 10). Surface morphology was analyzed by SEM and chemical elements were identified by EDX (n = 5). Data were evaluated by ANOVA and Tukey's test (α = 0.05). RESULTS: Most materials were not affected by HCl. FU showed the lowest Sa and Rv, and the highest GL after HCl. On the other hand, EF presented the highest Sa, Rv, and SL, and the lowest GL. The MI of materials was not changed after HCl. Topographical and chemical alterations were observed after HCl only for EF. CONCLUSIONS: The composites showed minor surface changes after HCl, which was not observed for the glass ionomer cement (EF). FU presented the best performance regarding the parameters evaluated. CLINICAL RELEVANCE: The effects of erosive challenge with HCl on composites were minimal, while the glass ionomer cements might not be indicated as restorative material for patients with gastroesophageal reflux disease.


Assuntos
Resinas Compostas , Ácido Clorídrico , Materiais Dentários , Cimentos de Ionômeros de Vidro , Humanos , Teste de Materiais , Propriedades de Superfície
8.
Dent Mater ; 38(6): 907-923, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35289283

RESUMO

OBJECTIVES: Etching approaches [37% phosphoric acid, self-etching, 10-3 solution (3% ferric chloride dissolved in 10% citric acid), or 1.4% nitric acid] were evaluated regarding enamel shear bond strength (24 h), dentin microtensile bond strength (24 h and 2 years), failure mode, enzymatic activity of the hybrid layer, and nanoleakage (24 h and 2 years) of Prime&Bond Universal (PBU, Dentsply-Sirona) and Gluma Bond Universal (GBU, Kulzer). METHODS: Adhesives were applied on blot-dried (wet-bonding, positive control) or air-dried (remaining groups) dentin after acid-etching (15 s) or in self-etch mode. Enamel and dentin bond strength tests used 160 human teeth (n = 10). Failure mode of tested samples and nanoleakage within the dentin-adhesive interface (n = 5) were analyzed by scanning electron microscopy. Dentin enzymatic activity was investigated by in situ zymography (n = 3). RESULTS: Enamel bond strengths did not differ statistically among groups. Wet-bonding with 37% phosphoric acid showed similar dentin bond strength compared to 10-3 solution or 1.4% nitric acid at 24 h for both adhesives. None of the etchants inhibited enzymatic activity, and all groups showed dentin bond strength reduction after 2-year storage. GBU showed higher nanoleakage. Experimental etchants did not affect enamel bond strength. Dentin bond strength was not stable after 2 years, despite promising 24-hour results. SIGNIFICANCE: This study suggests multiple etching approaches to optimize and achieve stable dentin bonding, while also offering in-depth information about the performance of recently released universal adhesive systems.


Assuntos
Colagem Dentária , Adesivos Dentinários , Colagem Dentária/métodos , Cimentos Dentários , Dentina , Adesivos Dentinários/química , Humanos , Ácido Nítrico , Cimentos de Resina
9.
Braz Dent J ; 32(3): 92-104, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34755794

RESUMO

This in vitro study evaluated the effect of the beam homogeneity of a multiple-peak light-curing unit on the surface microhardness and the effect of toothbrushing wear on the microhardness, surface roughness, roughness profile, volume loss, and gloss retention of incremental and bulk-fill resin-based composites (RBCs). A LED light-curing unit (VALO) with four LEDs at the tip end (405, 445, 465A, and 465B nm emission peak) was used according to each manufacturer-recommended time to obtain disks (n=10) of six RBCs: Estelite Sigma Quick, Charisma Classic, Tetric EvoCeram Bulk Fill, Filtek Z250, Filtek Supreme Ultra, and Filtek Bulk Fill. Microhardness values were obtained according to each LED positioning of the light-curing unit on the top surface of the RBCs and were analyzed before and after toothbrushing regarding microhardness, surface roughness, roughness profile, volume loss, and gloss retention. Microhardness was considered homogeneous on the top surface regardless of the type of RBC or wavelength tested (p>0.05). Overall, toothbrushing did not reduce the microhardness of the RBCs but influenced the gloss values for most RBCs (p<0.001). Charisma Classic presented the greatest surface roughness and roughness profile after toothbrushing (p<0.05). Volume loss did not differ among RBCs (p>0.05). In conclusion, different wavelengths of the LED did not affect the top surface microhardness, regardless of the RBCs tested; and bulk-fill composites presented similar surface changes (microhardness, surface roughness, roughness profile, volume loss, and gloss retention) when compared to conventional composites after toothbrushing.


Assuntos
Resinas Compostas , Materiais Dentários , Teste de Materiais , Polimerização , Propriedades de Superfície , Escovação Dentária
10.
J Adhes Dent ; 23(5): 409-420, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34549924

RESUMO

PURPOSE: This study evaluated dentin bond strength, failure mode, interface morphology, adhesive infiltration into dentin, and marginal adaptation of bulk-fill composites used with different adhesives. MATERIALS AND METHODS: Third molars received occlusal class I cavities (4 mm x 4 mm x 4 mm) that were bulk-filled with Admira Fusion x-tra (Voco) or SonicFill 2 (Kerr) using four adhesives (Scotchbond Multipurpose, 3M Oral Care; Clearfil SE Bond, Kuraray Noritake; OptiBond All-In-One, Kerr; Futurabond U, Voco). Scotchbond was used with acid-etching, while the remaining adhesives were applied in self-etch mode. Sixty-four teeth were selected for the microtensile bond strength test (n = 8). Failure modes were analyzed with scanning electron microscopy (SEM). Interface morphology and adhesive infiltration (n = 3) were investigated using confocal laser scanning microscopy (CLSM). Marginal adaptation (n = 3) was also evaluated using SEM. Bond strength, failure mode, and adhesive infiltration data were analyzed for distribution and homocedasticity, followed by appropriate statistical analyses (α = 0.05). RESULTS: Regarding bond strength, no differences were found among adhesives for SonicFill; Clearfil showed a significantly lower mean value than did Scotchbond (p ≤ 0.05) for Admira; the two composites did not differ. Adhesive and mixed failures were observed for all groups. Scotchbond led to thicker hybrid layers with deeper adhesive infiltration as opposed to Futurabond. The groups Admira+Futurabond, SonicFill+Clearfil, and SonicFill+Futurabond presented the highest marginal discontinuity. CONCLUSION: The tested bulk-fill composites did not affect dentin bonding. Scotchbond and Clearfil seem to be reliable for bonding SonicFill 2 to dentin. The performance of Futurabond was questionable, given its poor-quality interface and higher percentages of marginal gaps.


Assuntos
Colagem Dentária , Adesivos Dentinários , Adesivos , Resinas Compostas , Cimentos Dentários , Dentina , Teste de Materiais , Microscopia Eletrônica de Varredura , Cimentos de Resina , Resistência à Tração
11.
Braz. dent. j ; 32(3): 92-104, May-June 2021. tab, graf
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: biblio-1345500

RESUMO

Abstract This in vitro study evaluated the effect of the beam homogeneity of a multiple-peak light-curing unit on the surface microhardness and the effect of toothbrushing wear on the microhardness, surface roughness, roughness profile, volume loss, and gloss retention of incremental and bulk-fill resin-based composites (RBCs). A LED light-curing unit (VALO) with four LEDs at the tip end (405, 445, 465A, and 465B nm emission peak) was used according to each manufacturer-recommended time to obtain disks (n=10) of six RBCs: Estelite Sigma Quick, Charisma Classic, Tetric EvoCeram Bulk Fill, Filtek Z250, Filtek Supreme Ultra, and Filtek Bulk Fill. Microhardness values were obtained according to each LED positioning of the light-curing unit on the top surface of the RBCs and were analyzed before and after toothbrushing regarding microhardness, surface roughness, roughness profile, volume loss, and gloss retention. Microhardness was considered homogeneous on the top surface regardless of the type of RBC or wavelength tested (p>0.05). Overall, toothbrushing did not reduce the microhardness of the RBCs but influenced the gloss values for most RBCs (p<0.001). Charisma Classic presented the greatest surface roughness and roughness profile after toothbrushing (p<0.05). Volume loss did not differ among RBCs (p>0.05). In conclusion, different wavelengths of the LED did not affect the top surface microhardness, regardless of the RBCs tested; and bulk-fill composites presented similar surface changes (microhardness, surface roughness, roughness profile, volume loss, and gloss retention) when compared to conventional composites after toothbrushing.


Resumo Este estudo in vitro avaliou a homogeneidade do feixe de um fotopolimerizador de múltiplos picos na microdureza superficial e o efeito da escovação na microdureza, rugosidade superficial, perfil de rugosidade, perda de volume e retenção do brilho de compósitos a base de resina (RBCs) incrementais ou bulk-fill. Um fotopolimerizador LED (VALO) com quatro LEDs na ponteira (405, 445, 465A e 465B nm de pico de emissão) foi usado de acordo com o tempo recomendado por cada fabricante para obtenção de discos (n=10) de seis RBCs: Estelite Sigma Quick, Charisma Classic, Tetric EvoCeram Bulk Fill, Filtek Z250, Filtek Supreme Ultra e Filtek Bulk Fill. Os valores de microdureza foram obtidos seguindo o posicionamento de cada LED na superfície superior das amostras e foram analisados antes e após a escovação quanto a microdureza, rugosidade superficial, perfil de rugosidade, perda de volume e retenção do brilho. A microdureza foi considerada homogênea no topo da superfície, independentemente do tipo de RBCs ou comprimento de onda testados (p>0.05). No geral, a escovação não reduziu a microdureza das RBCs, mas influenciou o brilho para a maioria das RBCs (p<0.001). Charisma Classic apresentou os maiores valores de rugosidade superficial e perfil de rugosidade após a escovação (p<0.05). A perda de volume não diferiu entre as RBCs (p>0.05). Em conclusão, os diferentes comprimentos de onda do LED não alteraram a microdureza do topo da superfície, independentemente das RBCs testadas; e as resinas bulk-fill apresentaram alterações superficiais similares (microdureza, rugosidade superficial, perfil de rugosidade, perda de volume e manutenção do brilho) quando comparadas às resinas convencionais após a escovação.


Assuntos
Resinas Compostas , Materiais Dentários , Propriedades de Superfície , Teste de Materiais , Polimerização
12.
Braz Oral Res ; 32: e122, 2018 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-30569972

RESUMO

The effects of tooth brushing could affect the long-term esthetic outcome of composite restorations. This study evaluated the effect of two different emission spectrum light-curing units on the surface roughness, roughness profile, topography and microhardness of bulk-fill composites after in vitro toothbrushing. Valo (multiple-peak) and Demi Ultra (single-peak) curing lights were each used for 10s to polymerize three bulk-fill resin composites: Filtek Bulk Fill Posterior Restorative (FBF), Tetric EvoCeram Bulk Fill (TET) and Surefil SDR Flow (SDR). After 30,000 reciprocal strokes in a toothbrushing machine, the roughness profile, surface roughness, surface morphology, and microhardness were examined. Representative SEM images were also obtained. When light-cured with the Demi Ultra, SDR showed the most loss in volume compared to the other composites and higher volume loss compared to when was light-cured with Valo. The highest surface roughness and roughness profile values were found in SDR after toothbrushing, for both light-curing units tested. FBF always had the greatest microhardness values. Light-curing TET with Valo resulted in higher microhardness compared to when using the Demi Ultra. Confocal and SEM images show that toothbrushing resulted in smoother surfaces for FBF and TET. All composites exhibited surface volume loss after toothbrushing. The loss in volume of SDR depended on the light-curing unit used. Toothbrushing can alter the surface roughness and superficial aspect of some bulk-fill composites. The choice of light-curing unit did not affect the roughness profile, but, depending on the composite, it affected the microhardness.


Assuntos
Resinas Compostas/efeitos da radiação , Lâmpadas de Polimerização Dentária , Escovação Dentária/efeitos adversos , Análise de Variância , Resinas Compostas/química , Dureza/efeitos dos fármacos , Dureza/efeitos da radiação , Cura Luminosa de Adesivos Dentários/métodos , Teste de Materiais , Microscopia Confocal , Microscopia Eletrônica de Varredura , Polimerização , Reprodutibilidade dos Testes , Propriedades de Superfície/efeitos dos fármacos , Propriedades de Superfície/efeitos da radiação , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA